Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Rev. med. (São Paulo) ; 101(5): e-185868, set-out. 2022.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1395412

ABSTRACT

A oleorresina obtida de copaíferas é amplamente utilizada na medicina tradicional brasileira. Este estudo avaliou a composição química por Cromatografia Gasosa (CG) e o efeito da oleorresina de Copaifera officinalis em células-tronco. Para isso as células foram tratadas com a oleorresina nas concentrações de 0,5, 20, 110, 140, 170 ou 200 µg/ml por 24h. A avaliação por CG identificou os sesquiterpenos ß-cariofileno, trans-α-bergamoteno e óxido de cariofileno II como os compostos majoritários da oleorresina. As menores concentrações de oleorresina utilizadas apresentaram resultados semelhantes ao grupo controle e as maiores concentrações diminuíram significativamente a viabilidade celular e apresentaram maior citotoxicidade. Como conclusão, os principais componentes encontrados na oleorresina de copaíba foram os sesquiterpenos e as baixas concentrações testadas não foram citotóxicas. O aumento das concentrações de oleorresina de copaíba promoveu diminuição da viabilidade celular e aumento dos efeitos citotóxicos nas células-tronco. Embora a oleorresina de copaíba tenha uso etnofarmacológico na cicatrização, este estudo demonstrou efeito citotóxico em células-tronco, as quais estão relacionadas ao processo de regeneração corpóreo. Portanto, deve-se ter cuidado com a dosagem de oleorresina a ser utilizada, uma vez que este estudo in vitro mostrou citotoxicidade e um impacto negativo na viabilidade das células-tronco nas mais altas concentrações testadas. [au]


Oleoresinobtained from Copaifera trees is extensively used in Brazilian traditional medicine. This study hasevaluated the chemical composition and effect of Copaifera officinalisoleoresin on stem cells. The oleoresin was analyzed by Gas Chromatography (GC) and the cells were treated with the oleoresin at concentrations of 0.5, 20, 110, 140, 170 or 200 µg/ml for 24h for cellular tests. GC identified the sesquiterpenes beta-caryophyllene, trans-alpha-bergamotene, and caryophyllene oxide II as the main compounds in oleoresin. The cell viability and cytotoxicity assays showed the lowest concentrations of oleoresin used presented similar results to the control group and the higher concentrations tested significantly decreased cell viability and increased cytotoxicity. In a conclusion, the main components found in copaiba oleoresin were sesquiterpenes and the low tested concentrations were not cytotoxic. The increased concentrations of copaiba oleoresin promoted a decrease in cell viability and an increase of cytotoxicity in the stem cells. Although copaiba oleoresin has ethnopharmacology use in healing, this study showed toxicity in stem cells, which are related to the corporeal regeneration process. Therefore, caution must be taken with the dosage of the oleoresin to be used since this in vitro study showed cytotoxicity and a negative impact on stem cell viability at the higher tested concentrations. [au]

2.
J. bras. patol. med. lab ; 51(4): 224-228, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-759320

ABSTRACT

ABSTRACTIntroduction:Currently, the cytological analysis of biological fluids, such as peritoneal fluid, is performed by manually cells counting in Fuchs-Rosenthal chamber. However, this method has a number of limitations. Because of these limitations, automatic counters have been evaluated for cell counting in this type of sample in order to make it faster and more reliable test.Objective:The aim of this study is to compare the manual and semi-automated leukocytes and erythrocytes counting in peritoneal fluid.Materials and methods:The samples were analyzed manually and using the CountessTM(Invitrogen).Results:The results showed that although there is a correlation between the two counting methods, the correlation is relatively low, for both leukocytes and erythrocytes analysis.Conclusion:The results suggest that peritoneal fluid should continue to be analyzed in Fuchs-Rosenthal chamber. However, further studies should be conducted with a greater number of samples to investigate the possibility of using automated cells counting in serous fluids and, thus, provide greater speed and quality of results.


RESUMOIntrodução:Atualmente, a análise citológica de líquidos biológicos, como líquido peritoneal, é realizada por meio da contagem manual de células, em câmara de Fuchs-Rosenthal. Porém, esse método apresenta uma série de limitações. Com isso, contadores automáticos têm sido avaliados para a contagem de células nesse tipo de amostra a fim de tornar esse exame mais rápido e confiável.Objetivo:Comparar a contagem manual e semiautomatizada de leucócitos e eritrócitos em líquido peritoneal.Materiais e métodos:As amostras foram analisadas manualmente e no contador de células CountessTM (Invitrogen).Resultados:Os resultados mostraram que apesar de existir correlação entre os dois métodos de contagem, essa correlação é relativamente fraca, tanto para análise de leucócitos como para de eritrócitos.Conclusão:Esses resultados sugerem que o líquido peritoneal deve continuar a ser analisado em câmara de Fuchs-Rosenthal, contudo novos estudos devem ser realizados, com maior número de amostras, para investigar a possibilidade do uso de automação na contagem de células em líquidos serosos e, assim, proporcionar maior agilidade e qualidade no resultado.

3.
Psychol. neurosci. (Impr.) ; 1(1): 47-54, Jan.-June 2008.
Article in English | LILACS | ID: lil-614715

ABSTRACT

The last few years have seen a growing interest in stem cell research. The media has helped to keep attention to the subject making it as popular as therapeutic cloning. A number of studies highlighted the importance of stem cells as prospective therapy for neurodegenerative conditions. The possibility of successful treatment for such pathologies using stem cells has raised enormous hope. Whilst in some countries biotechnologists have realised the commercial potential of the field, human stem cell research and its clinical applications have constantly been subject of ethical and legal debate. The present review brings an overview of recent aspects of stem cell research for central nervous system disorders, with special attention to Parkinson's and Alzheimer's diseases, cerebral ischemic insult and spinal cord injury. Furthermore, the ethical implications regarding the use of embryonic stem cells as a fundamentally more promising cell type are discussed.

4.
Rev. bras. anal. clin ; 40(1): 25-30, 2008. tab
Article in Portuguese | LILACS | ID: lil-510671

ABSTRACT

As células-tronco são células capazes de gerar diferentes tipos celulares. Entre as fontes de células-tronco encontra-se osangue de cordão umbilical que apresenta um grande número de progenitores hematopoéticos. Essa fonte vem sendo amplamente utilizada em transplantes devido a diversas vantagens, entre elas, a imediata disponibilidade, beneficiando pacientes com doenças hematológicas e imunológicas. Para o sucesso dos transplantes, há a necessidade de se considerar a freqüência das células-tronco nas amostras de sangue de cordão umbilical. Marcadores celulares específicos como a presença da molécula CD34 e a ausência de CD38 indicam o grau de imaturidade das células-tronco hematopoéticas e, conseqüentemente, a sua grande capacidade de proliferação e diferenciação celular. Existem diferenças quanto à freqüência das células-tronco no sangue de cordão umbilical entre neonatos nascidos a termo e prematuros. Essas diferenças podem ser importantes na escolha das amostras armazenadas nos bancos de sangue de cordão umbilical a serem utilizadas nos transplantes de células-tronco. Além disso, as pesquisas com células-tronco têm mostrado grande capacidade de proliferação e diferenciação em vários tecidos. O estudo das células-tronco pode ser a resposta para o tratamento de doenças cardíacas, neurológicas e imunológicas de inúmeros pacientes e, talvez, o primeiro passo para a cura.


Stem cells are cells that have the ability to give rise to different cell types. Among the sources of stem cells, there is the umbilical cord blood, which has a great number of hematopoietc progenitors. This source has been widely used in transplants owingto its advantages like, for example, immediate availability, improving patients with immunological and hematological diseases. In order for the transplant to be successful, it is necessary to consider the stem cell frequency within the samples of the umbilical cord blood. Specific markers like the presence of CD34 molecule and the absence of CD38 indicates the immature level of hematopoietic stemcells and consequently their ability of cellular proliferation and differentiation. There are differences between the cellular frequency in umbilical cord blood from preterm and term newborn. These differences might be important in order for finding a sample stored atumbilical cord blood banks for the transplant. Nevertheless, research using stem cells has attempted that these cells have a great capacity of proliferation and differentiatin into many tissues. Stem cell research offers hope for the treatment of cardiac, neurological and imunological diseases of countless patients and, perhaps, the first step to the cure.


Subject(s)
Humans , Infant, Newborn , Hematopoietic Stem Cells , Infant, Premature/blood , Stem Cells , Fetal Blood/transplantation , Umbilical Cord
5.
Biocell ; 31(3): 397-403, Sept.-Dec. 2007. graf, tab
Article in English | LILACS | ID: lil-633243

ABSTRACT

The use of umbilical cord blood stem cells is an efficient alternative for the transplantation of hematopoietic progenitor cells. A number of factors can influence the volume and amount of CD34+ cells, which are considered as immature and capable of proliferation. Quantification of CD34+ cells, evaluation of CD38 and c-kit molecules on these cells, as well as correlations of such factors as maternal age, gestational age, newborn sex and weight, umbilical cord length, placental weight with increased volume and concentration of immature cells, among others, were performed in 70 blood samples from term newborns. The mean volume of umbilical cord blood collected was 53.8±33.6 mL, where 30.96±18.9 CD34+/mL UCB cells were found, of which 16.66±8.32% were CD34+CD38- cells, and 47.23±24.0% were CD34+CD117cells. Newborn weight and placental weight were positively correlated with increased volume of collected UCB. The volume of collected blood was found to affect the absolute count of CD34+ cells and the relative value of these among total nucleated cells, as well as the percentage of CD34+CD117+ and CD34+CD117cells. CD34+ cells were positively correlated with leukocytes, and gestational age was negatively correlated with the number of CD34+ cells. Our results confirm the importance of the accurate quantification of CD34+ cells and their subsets, and that many factors may be related to the higher number of hematopoietic stem cells, which are crucial for successful transplantation.

6.
Rev. Inst. Adolfo Lutz ; 66(3): 213-224, set.-dez. 2007. tab
Article in English | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-IALPROD, SES-SP | ID: lil-500675

ABSTRACT

Stem cells are undifferentiated cells that are capable of both self-renewal and giving rise to several cell types. Cardiovascular disease is the most important cause of death in westerns society and, in spite of therapeutic advances in traditional medicine, it has not been possible to recover the original cardiac function. Similarly, Chagas' disease is an important cause of heart failure in Latin America. The differentiation capacity of stem cells makes them an important source of cells for the regeration of cardiac tissue. Research using animal models of myocardial infarction has shown promissing results for the use of stem cells in heart disease therapy. Recent clinical trials have shown the safety and benefit of therapy with stem cells in cardiac regeneration. Research in this field is still in the early stages and needs to be consolidated to permit wider use of stem cells in clinical medicine. Nevertheless, cell therapy has been shown to have potential as a new approach in the treatment of heart disease, which takes the lives of millions people around the world.


Subject(s)
Heart/physiology , Stem Cells , Chagas Disease , Myocardial Infarction , Regeneration , Cell- and Tissue-Based Therapy
7.
Rev. Inst. Adolfo Lutz ; 65(3): 146-156, set.-dez. 2006.
Article in Portuguese | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-IALPROD, SES-SP | ID: lil-461269

ABSTRACT

As células-tronco são capazes de dar origem a diferentes tecidos e órgãos. Muitos artigos e experimentoscientíficos têm sido realizados com o intuito de conhecer melhor os mecanismos pelos quais essas células agem para regenerar os tecidos danificados e na atividade terapêutica de doenças incuráveis. O fígado possui uma notável capacidade de auto-reparo. As células hepáticas envolvidas na regeneração do fígado expressam os muitos dos marcadores presentes nas células-tronco hematopoéticas. Além disso, já foi demonstrado que as células da medula óssea podem originar células do epitélio hepático. Neste contexto, pode-se sugerir que as células-tronco desempenham um papel de suma importância no reparo das células hepáticas lesadas.


Subject(s)
Stem Cells , Liver , Hepatocytes , Liver Regeneration
10.
Rev. bras. hematol. hemoter ; 26(3): 159-166, 2004. tab, graf
Article in Portuguese | LILACS | ID: lil-396481

ABSTRACT

Os aparelhos de automação em hematologia oferecem alta sensibilidade e precisão na realização do hemograma na rotina do laboratório de hematologia. Para avaliar os critérios de liberação dos hemogramas por interfaceamento direto entre os contadores eletrônicos e o setor de emissão dos laudos, foram examinadas 247 lâminas de hemogramas. Entre essas, 149 lâminas foram consideradas concordantes com os critérios de liberação por interfaceamento direto enquanto 98 foram consideradas não concordantes pelos contadores automatizados Sysmex SE 9500 e Cell Dyn 4000. Dentre os hemogramas concordantes, a microscopia sem acesso aos dados numéricos mostrou alteração em apenas uma lâmina, a qual era clinicamente irrelevante. Por outro lado, entre os 98 hemogramas não concordantes, 32 apresentavam alterações. Os dados encontrados comprovam a satisfatória sensibilidade dos sistemas de automação analisados. As lâminas dos hemogramas não concordantes foram reexaminadas, com o objetivo de avaliar os resultados eletrônicos. Esse fato permitiu a análise das causas das reprovações com sugestões para eventuais simplificações do sistema. O presente trabalho mostrou que os resultados emitidos pelos contadores automáticos analisados apresentam uma alta correlação com a avaliação microscópica. Conclui-se, portanto, que os resultados dos hemogramas liberados pelos aparelhos analisados são satisfatórios e estes aparelhos são confiáveis para a rotina no laboratório de hematologia.


Automated equipment used in the hematological laboratory forroutine hemograms offers high sensitivity and great accuracy. Inorder to evaluate the liberation criteria of hemograms by directinterfacing between the electronic counters and the emission ofresults, 247 hemogram slides were examined. Of these using theSysmex SE 9500 and Cell Dyn 4000 automated counters, 149slides were considered concordant with liberation criteria bydirect interfacing while 98 were considered non-concordant. Ofthe concordant hemograms, microscopy without access to thenumeric results showed alterations in only one slide, which wasconsidered clinically irrelevant. On the other hand, of the 98non-concordant hemograms, 32 showed alterations. The resultsdemonstrate the satisfactory sensitivity of the automatic systemsanalyzed. The slides with the non-concordant hemograms werere-examined, in order to evaluate the electronic results. Thus, itwas possible to analyze the causes of the non-concordance andgive suggestions for possible simplifications of the system. Thisstudy shows that the results emitted by the assessed automaticcounters presented a high level of correlation with the microscopycount. Therefore, it can be concluded that the results of thehemograms liberated by the devices are satisfactory and that thesedevices are reliable for the routine use within the hematologicallaboratory. Rev. bras. hematol. hemoter. 2004; 26(3):159-166.


Subject(s)
Humans , Clinical Laboratory Techniques , Blood Cell Count/instrumentation , Leukocyte Count/instrumentation , Diagnosis, Computer-Assisted/instrumentation , Evaluation Studies as Topic , Image Interpretation, Computer-Assisted , Image Processing, Computer-Assisted
11.
Rev. Inst. Adolfo Lutz ; 53(1/2): 5-10, 1993. ilus, tab
Article in Portuguese | LILACS, SES-SP | ID: lil-141013

ABSTRACT

Os metabólitos tóxicos Aflatoxinas(AFL) B1,B2,G1 e G2, säo produzidos por linhagens de fungos Aspergillus flavus e A.parasiticus, Ocratoxina A (OCT) produzida por A.ochraceus e várias espécies de Penicillium e a Zearalenona(ZEA) pelo Fusarium graminearum. Estas micotoxinas foram pesquisadas em 519 amostras de diferentes substratos constituídos especialmente de milho e raçäo balanceada, além de outros produtos utilizados na alimentaçäo animal como arroz, sorgo, farelo de trigo e colza, provenientes do Brasil e uma amostra da Argentina durante o período compreendido entre os anos de 1987-1991. Foi empregado o método SOARES&RODRIGUES-AMAYA para extraçäo e quantificaçäo das micotoxinas, com limites de detecçäo de 4,5, 60p.p.b. para Aflatoxinas, Ocratoxina A e Zearalenona, respectivamente. Em 68,59 por cento das amostras näo foram detectadas estas micotoxinas, mas 24,86 por cento das amostras positivas estavam contaminadas por Aflatoxinas, 1,73 por cento por Ocratoxina A e 4,82 por cento das amostras estavam contaminadas por Zearalenona. O nível máximo de contaminaçäo por Aflatoxinas foi de 1906p.p.b., de 745p.p.b. por Ocratoxina A e de 4982p.p.b. por Zearalenona. Frente aos resultados obtidos, sugere-se o monitoramento constante destas micotoxinas, principalmente Aflatoxinas, por parte da indústria e a atençäo dos produtores de aves e suínos, pois estas micotoxinas comprometem a saúde animal e, por consequência, o desempenho produtivo destes animais


Subject(s)
Zearalenone , Aflatoxins , Mycotoxins/analysis , Ochratoxins , Animal Feed , Brazil , Chromatography, Thin Layer , Food Contamination
SELECTION OF CITATIONS
SEARCH DETAIL